How to Use the Decibel Meter
Out of the box the meter shows relative dBFS from your device microphone, with a 3-second peak hold and green, amber, and red zones. It only displays dB SPL after you calibrate it against a known reference source, and even then a phone is not a certified sound level meter.
Before you start
- Close other apps that might be using the microphone.
- Remove a thick phone case that covers the microphone port.
- On iOS installed web apps, microphone access may be restricted; open the page in Safari if the mic will not start.
Step by step
- Enable the microphone — Tap Enable Microphone and allow access. If access is denied, allow microphone permission in your browser settings, then try again.
- Read the level — Without calibration the Level readout is dBFS, a relative digital level where 0 is the loudest the device input can register. Values are negative and only comparable on the same device.
- Watch the peak — The Peak readout holds the highest level from the last 3 seconds so short hits are not missed.
- Choose weighting — Flat is unweighted signal level. A-weighted (dBA) de-emphasizes low frequencies the way hearing-exposure measurements do.
- Choose ballistics — Under Ballistic, Fast (125 ms) follows speech and transients; Slow (1 s) gives a steadier number for steady noise.
- Calibrate only with a reference — Open Calibrate meter, hold a known steady SPL source such as a 94 dB acoustic calibrator at the mic, enter its Reference level, and Save calibration. The display then reads dB SPL. Use Clear calibration to return to dBFS.
Practical example: Comparing two PA zones before doors
Set Flat and Slow, then stand at the same height at the center of zone A while pink noise plays quietly. Note the dBFS level, walk to zone B, and compare on the same device. A lower reading is a reason to investigate coverage, placement, and device gain processing—not proof that more volume is needed. Confirm with a measurement system before changing the PA.
Safety and limitations
- Uncalibrated readings are dBFS, not dB SPL. Do not quote them as sound pressure levels.
- Phone microphones and automatic gain processing vary by model; calibration is stored for this device and browser only.
- This is not a Type 1 or Type 2 sound level meter. Do not use it for regulatory compliance or official hearing-conservation records.
- Very loud sources can overload the device microphone, so readings near the top of the scale may be compressed.