How to Use the Signal Generator
The Signal Generator creates test signals in the browser, with no file to download. It offers Pink, White, Brown, Blue, Sine, and Polarity modes, and each mode lists use cases plus what to listen or watch for.
Before you start
- Connect the device output to the system at a mixer line input, or use the device speaker for quick checks only.
- Pull the channel fader down and set the device volume low before you start a signal.
- Tell everyone in the room before you send noise through the PA.
Step by step
- Choose a mode — Pink is equal energy per octave for EQ and room tuning. White is flat per Hz for equipment testing. Brown is low-frequency heavy for subs. Blue tilts toward highs. Sine is a pure tone. Polarity is an asymmetric pulse for cone direction checks.
- Set the frequency for Sine — In Sine mode use the Frequency control to pick a tone, for example stepping through 100 Hz, 1 kHz, and 10 kHz to check each driver.
- Set the output level — Use the Volume / Output Level control. Start low, then bring up the mixer fader to the level you need.
- Start and stop — Use Start signal (or Tap to start) and Stop signal. Stop the signal before re-patching anything.
- Follow the checklist — Read What to listen / watch for under the chosen mode, such as cones that should push outward together in Polarity mode.
Practical example: Checking a pair of tops after a re-cable
Patch the device into a spare line channel, pick Pink, and walk each speaker at a low level to confirm every box is passing audio. Switch to Polarity and watch or feel the woofer of each cabinet: all cones should push outward together. A cone pulling in suggests a reversed cable or amplifier channel.
Safety and limitations
- Test signals can damage drivers and hearing when played loud. Raise level gradually and never sweep sine tones at high level through tweeters.
- The device's own output stage limits low-frequency and high-frequency accuracy; it is not a laboratory generator.
- Polarity checks with a pulse are a field check. Confirm with a dedicated polarity tester or measurement system for critical rigs.